Classification: E81T1-K2M-J (AWS A5.29)
Flux-cored wire · Lincoln Electric
Price on request
Prices for this catalogue are not published; every quotation is prepared for the requested quantity and delivery terms.
Key features
- Rutile flux cored gas shielded 1.5% Ni, Ti and B alloyed flux cored wire with very good impact toughness down to -60°C.
- Best in class consumable for welding of wind mill foundations and applications in offshore oil and gas and structural segments. Superior weldability, low spatter, good bead appearance.
- Exceptional mechanical properties (CVN >80J at -60°C).
- Superior product consistency with optimal alloy control
- Can be applied for applications requiring CTOD testing.
Standards and classifications
| AWS A5.29 | E81T1-K2M-J |
|---|---|
| EN ISO 17632-A | T 50 6 1.5Ni P M 2 H5 |
Chemical composition
(Weight %), typical, all weld metal
| Shielding gas | C | Mn | Si | P | S | Ni | HDM |
|---|---|---|---|---|---|---|---|
| M21 | 0.04 | 1.4 | 0.2 | 0.012 | 0.010 | 1.4 | 3 ml/100 g |
Mechanical properties
- , TYPICAL, ALL WELD METAL
- Shielding
- gas Condition*
- Yield
- strength
- (MPa)
- Tensile
- strength
- (MPa)
- Elongation
- (%)
- Impact ISO-V (J)
- -40°C -50°C -60°C
- Required: AWS
- A5.29 min. 470 550-690 min. 19 min. 27
- EN ISO 17632-
- A min. 500 560-720 min. 18 min. 47
- Typical values M21 AW 590 630 23 130 100 80
- * AW = As welded
Welding positions
All positions except vertical down
Current type
DC+
Shielding gas
| Designation (EN ISO 14175) | Type | Composition |
|---|---|---|
| M21 | Mixed gas | Ar+ (>15-25%) CO₂ Flow rate 15-25 l/min |
Approvals
LRDNVRINA
Versions and packaging
| Item number | Diameter (mm) | Net weight (kg) | Packaging |
|---|---|---|---|
| 941395N | 1.2 | 16.0 | |
| 941494N | 16.0 | SPOOL (S300) 16.0 941272N, |
Availability of individual item numbers is confirmed with the quotation.
Related products
Products in the same category from the same brand.
Product inquiry
Send an inquiry and we will come back with availability and a quotation.