Lincoln Electric · Flux-cored wire

Pipeliner® G80M-E

Lincoln Electric
Pipeliner® G80M-E Flux-cored wire

Classification: E91T1-GM (AWS A5.29)

Flux-cored wire · Lincoln Electric

Price on request

Prices for this catalogue are not published; every quotation is prepared for the requested quantity and delivery terms.

Key features

  • Flux cored wire for mechanised and semi-automatic welding with increased deposition rate (kg/h).
  • Perfect bead profile for fill and cap passes.
  • Easy to remove, reduces cleaning time and improves operating factors.
  • Focused and clearly visible arc column offers easier welding and reduces operator training time.
  • A concentrated and deeply penetrating arc helps to achieve optimal quality of welds.
  • Very low hydrogen (HDM <4 ml/100g) and long term resistance against moisture pick-up in vacuum sealed packaging.

Standards and classifications

AWS A5.29E91T1-GM
EN ISO 17632-AT 55 4 1NiMo P M 2 H5

Chemical composition

(Weight %), typical, all weld metal

Shielding gasCMnSiNiPSMo
M210.061.40.30.950.0130.0100.4

Mechanical properties

  1. , TYPICAL, ALL WELD METAL
  2. Shielding gas Condition* Yield strength
  3. (MPa)
  4. Tensile strength
  5. (MPa)
  6. Elongation
  7. (%)
  8. Impact ISO-V
  9. (J)
  10. -40°C
  11. Required: AWS
  12. A5.29 min. 540 620-760 min. 19
  13. EN ISO 17632-A min. 550 640-820 min. 18 min. 47
  14. Typical values M21 AW 695 740 21 65
  15. * AW = As welded

Welding positions

All positions except vertical down

Current type

DC+

Shielding gas

Designation (EN ISO 14175)TypeComposition
M21Mixed gasAr+ (>15-25%) CO₂ Gas flow 15-25l/min

Versions and packaging

Item numberDiameter (mm)Net weight (kg)
9442531.24.5

Availability of individual item numbers is confirmed with the quotation.